General specifications
|
Signal type
|
Digital Input
|
Functional safety related parameters
|
Safety Integrity Level (SIL)
|
SIL 2
|
Supply
|
Connection
|
Power Rail or terminals 9+, 10-
|
Rated voltage
|
19 ... 30 V DC
|
Ripple
|
≤ 10 %
|
Rated current
|
≤ 30 mA
|
Power dissipation
|
≤ 500 mW
|
Power consumption
|
≤ 500 mW
|
InputKCD2-SR-EX1.LB倍加福安全柵
|
Connection side
|
field side
|
Connection
|
terminals 1+, 2-
|
Rated values
|
acc. to EN 60947-5-6 (NAMUR)
|
Open circuit voltage/short-circuit current
|
approx. 10 V DC / approx. 8 mA
|
Switching point/switching hysteresis
|
1.2 ... 2.1 mA / approx. 0.2 mA
|
Line fault detection
|
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
|
Pulse/Pause ratio
|
min. 20 ms / min. 20 ms
|
OutputKCD2-SR-EX1.LB倍加福安全柵
|
Connection side
|
control side
|
Connection
|
output I: terminals 5, 6 ; output II: terminals 7, 8
|
Output I
|
signal ; relay
|
Output II
|
signal or error message ; relay
|
Contact loading
|
253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load
|
Minimum switch current
|
2 mA / 24 V DC
|
Energized/De-energized delay
|
≤ 20 ms / ≤ 20 ms
|
Mechanical life
|
107 switching cycles
|
Transfer characteristics
|
Switching frequency
|
≤ 10 Hz
|
Galvanic isolation
|
Input/Output
|
reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
|
Input/power supply
|
reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
|
Output/power supply
|
reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
|
Output/Output
|
reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
|
Indicators/settings
|
Display elements
|
LEDs
|
Control elements
|
DIP-switch
|
Configuration
|
via DIP switches
|
Labeling
|
space for labeling at the front
|
Directive conformity
|
Electromagnetic compatibility
|
|
|
Directive 2014/30/EU
|
EN 61326-1:2013 (industrial locations)
|
Low voltage
|
|
|
Directive 2014/35/EU
|
EN 61010-1:2010
|
Conformity
|
Electromagnetic compatibility
|
NE 21
|
Degree of protection
|
IEC 60529:2001
|
Ambient conditions
|
Ambient temperature
|
-20 ... 60 °C (-4 ... 140 °F)
|
Mechanical specifications
|
Degree of protection
|
IP20
|
Connection
|
screw terminals
|
Mass
|
approx. 100 g
|
Dimensions
|
12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
|
Mounting
|
on 35 mm DIN mounting rail acc. to EN 60715:2001
|
Data for application in connection with hazardous areas
|
EU-Type Examination Certificate
|
BASEEFA 06 ATEX 0092
|
|
Marking
|
II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I
|
|
Input
|
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
|
|
Voltage
|
10.5 V
|
|
Current
|
17.1 mA
|
|
Power
|
45 mW (linear characteristic)
|
Supply
|
|
|
Maximum safe voltage
|
253 V AC (Attention! Um is no rated voltage.)
|
Output I, II
|
|
|
Maximum safe voltage
|
253 V AC (Attention! Um is no rated voltage.)
|
|
Contact loading
|
253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load
|
Certificate
|
PF 06 CERT 0972 X
|
|
Marking
|
II 3G Ex nA nC IIC T4 Gc
|
Output I, II
|
|
|
Contact loading
|
50 V AC/2 A/cos φ > 0.7; 30 V DC/2 A resistive load
|
Galvanic isolation
|
|
|
Input/Output
|
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
|
|
Input/power supply
|
safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
|
Directive conformity
|
|
|
Directive 2014/34/EU
|
EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
|